Also installed a brand new circuit box to allow for the bigger pump its a 20A GFCI breaker with 12 gauge wire going to the pump. If i knew what make/model of pump you have, I could be more specific. Ive been told my Hayward Vsp has been shutting itself off for low power issues, even though no power issues are present. thank you. Any new postings here are unlikely to be seen or responded to by other members. If not, I would suspect voltage issues, especially with the overheating, be sure pump is wired to accept the incoming voltage (115V or 230V), and it doesnt fluctuate more than 10%, +/- . I used electrical tape so the impeller Hi Rod, if the pump motor was submerged, then it is D.O.A. My pool guy went directly to saying I need a new one. Check that the shaft spins properly, and recheck all wiring. PDF | On Jan 1, 2009, Eduardo Keegan and others published Cognitive-behavior therapy. Thanks. So I installed a brand new Hayward W3SP2610X15 Super Pump Pool Pump, 1.5 HP last season Summer 2019 and used the electric cord from the old one which was showing its age. Inspect and clean your cell. Ours is doing the same thing. the motor makes humming sound but nothing happened, then the motor became burning hot. Another possibility could be a clogged pump impeller, should have mentioned that earlier. 14 x 28 inground, water clear. The breaker on the panel tripped. Do you have any suggestions? Zero on the gauge indicates no water flow, so if not an air leak it could be a clogged line, pump basket or impeller. It overheated very badly, even burning the hayward sticker off the pump itself maybe a month ago. Vacuum hose air leaks from splits in an old hose. Thank You, Thank You, Thank You! Hi Mary, pump motors have a thermal overload switch, which trips when motor gets too hot, it resets itself when the motor cools down, and the motor should restart again on its own. Sounds like you might have enough good parts to put together one good pump! Fault with the pump wiring. When the centrifugal switch is pushed flat by the spinning shaft (or with your finger [power off! It just started leaking at the top plumbing connection. Informacin detallada del sitio web y la empresa: cd77petanque.com Comit de seine et marne de ptanque I checked the breakers, plumbing, control panel, plumbingjust need to know if I shud prepare myself to buy a replacement. Low speed should be enough flow to activate the flow switch. Hi, that could be many things, from low water level to a broken impeller, but its usually an air leak. This new one when turned on seems to start, and pump, but the breaker shuts off in probably less than a second. If your cell looks like 4A, continue to Step 4. Hi Jodi, that could be two things either the pump impeller is severely clogged, keeping the motor shaft from turning or if the shaft spins freely, it is likely the capacitor (black cylinder in rear of motor) that has failed. I hope new filters fix the problem!!! . If the flow is normal however, it could be a bad flow switch or pressure switch. When in front of the pump, problems like a clogged impeller, air leak into the pump, or clogged skimmer line, or low water these will produce filter pressure lower than normal (on the filter pressure gauge). Hi Jim, make sure the shaft of the motor (and the impeller) is spinning freely, rust can build up internally, and create a frozen pump in spring. Hi Virgil, the time clock may not be set, or if you have a controller, the on/off program may not be setup, so it runs until it is set to turn off but is not set to turn back on again? When I turn on my clock and put my ear close to the clock I hear the clock sound like its on but my Hayward filter does not turn on and makes no noise. Any help,appreciated. The box is reading no water flow and psi is just above 0. I have no display showing. So, that leads me to the hose having splits, and drawing air in from a few small slits or holes in the hose, or else the hose is crimping due to the strong suction of the pump. It could also be a loose switch in the back of the motor. Hi Kelly, the first thing that comes to mind when you say pump stuck, is the common occurrence of rust building up between the rotor and stator, inside the motor. "thumbnailUrl": "https://x1.adis.ws/v1/media/graphics/i/lesl/its-logo-wide",
I shut the pump down the other night and it will not run. Mendorong partisipasi dunia dalam pengembangan teknologi jaringan baru, and vinylfor the first time ever on camera. 2. pump lid Find these plugs and remove them by loosening the wingnut and wiggling it out. Hi Jim, yes it could be leaking, around the stem that sticks up thru the valve body and attaches to the handle. What do you have the output percentage set to? Do you have any suggestion for similar pump? (or 110V, if wired 120V). Hi, Automatic restart 2 min after error is corrected. Hello, Just bought a house with a pool in January. I have a Hayward Perflex DE filter brand new last year. Is that a result of all the water that got in the equipment during the storm? "dateModified": "05/20/2022",
Also check other possible pressure side problems, like a closed or broken exit valve on the filter, or other restrictions further down the line, up to the pool return fittings. Hi John, you have to do it in tiny increments, with the wrench in place, just jiggle it around back of forth thru the range of motion (about 1/2), then once you can turn it enough to reposition the wrench, do that and jiggle again, working it for several minutes until you can get it to rotate a few revolutions. No matter where we move dial we have water coming out the back wash pipe. Well the electrician said it was a bad motor and to contact hayward to replace. Hooked it up the same as the last motor and left the setting to 230 as that is what the last motor was set to run on. The AquaTrol Are T-Cells interchangeable on Hayward AquaRite Systems? If your pump has an open bracket (where you can see the motor shaft), you can grab the shaft with your fingers or straight pliers, to break any rust. Now assuming your pressure gauge is accurate, 20 psi would tell me that your filter grid fingers need a serious cleaning. Do you know what the suggested torque is for the housing cap screws? If you suspect your breaker has broken, call a certified electrician to further diagnose the problem. it does not turn on even though i get 240 volts.My blower is on a different circuit and works properly with 240 volts. from I swapped the pump assembly with an almost identical Hayward that I found in the garage (bonus!) Should have the hard plastic side facing the motor and the soft rubber side facing the impeller. Hmmm, thats interestng, but I dont think you have a pump problem. I replaced the capacitor last year. When it shuts off, you could also test power, to be sure power is still reaching the motor, with a multimeter tester. If still nothing, look for damage in the rear of the motor, something burned, melted, loose, or pinched or cut wires. Hi LInda, humming or buzzing, and not starting could be a few things first check that the shaft is spinning, either by spinning on the impeller end, or at the rear of the motor (power Off in both cases), to be sure the shaft is not bound up or seized. RPS. If the filter was a problem, you may notice higher than normal filter pressure (compared to the old pump). It works fine otherwise, but the only way to stop it from heating up to 104 is by turning the power off to the heater. If the blower prover switch does not close after the blower starts the control will stop the ignition trial go into lockout. use a wrench on the rear of the shaft (or large flathead),to work the shaft back and forth until it spins freely. If it is still making chlorine and no real faults are flashing on the control, I wouldnt be too worried about it. Filter primes and runs great with no air bubbles try to let it run all night to get ready for season. IE9 and older versions are not supported. I hadnt run my pumps in a couple of weeks. Came out tonight and flipped the switch and pump started. No reset on the pump motor, but a little water on the wiring, and it will pop a GFI outlet. If low flow is not caused by a clogged strainer, inspect the cleaner hose for pressure loss (leaks). Professional Profile, View All Did not raise red flags, amature lol. Air can also be drawn into the pump from leaky suction side valves (skimmer or main drain). When I finally turned it off again it would not come back on. I have a new pump and brand new grid inside my filter i have no leaks after about 10 minutes my jets stop i back wash filter and it works for about 10 min again i am stumped. Strange things that when I have a storm it doesnt break but I does a day after when day is perfect. Hi, I have 2 issues with my 1530 above pool. Click here to shop our store. Troubleshooting Guides; Troubleshooting Guides. Hello, we have a 2 speed Hayward Tgistar pump it just stopped running, I have east the breakers both at the controller and on the main panel, the pump is hot to the touch and will restart after about two minutes then shutdown again. Hi Brian, is this a DE filter? You are using an out of date browser. Now when we try to turn everything on the pump wont start at all and keeps tripping the breaker. No special tools or lube needed. (Yes, literally now.). Hi David, an air leak will always come from a point BEFORE the impeller. I did notice the on/off switch was mushy moving from the on and off positions. Does the capacitor look bulged, cracked or leaking? If your pump plugs-in to an outlet, it could also be a bad outlet, or bad wire or connection from breaker to outlet. You are also using the diffuser? Do you have to find the pump up with water before turning it on? last year, I replaced the Sand & O ring on the filter, and I resealed the O ring on both the filter & Pump with O ring lube. If the spa is draining while in spa mode, it must be sending some water back to the pool, either the valve is not closing all the way, allowing some water to return to the pool. Hi there. Check if the pump will now run. All my piping is under concrete and will be very expensive to dig up. Secondly, it could be an air leak after the pump, around the filter, causing air to leak in when the pump shuts off (would be a water leak when the pump is on), which causes the water to drain out of the pump and back to the pool. We opened our pool today. which can clog the tiny gears, or wire issues, burned spots or chewed wires (ants). Turned it off and then tried it again and it hummed for a few and the something glowed red and then stopped humming. We have a Hayward Super Pump 260710 that is 1 hp.The pool was working fine when we opened it 1 week ago except after it would run for 15-20 mins the motor would trip the circuit breaker so we had an electrician replace the motor and check the electrical and that was fine; however, we cant get the pump primed. "url": "https://x1.adis.ws/v1/media/graphics/i/lesl/its-logo-wide"
Hi Jim, as I like to say, the problem lies, where the power dies. However after shutting it manually, the pump wouldnt start again. Hi Bill, when it goes into spa mode, the spa drain valve should open, and close off the pool suction valves, so that all the water is coming into the pump from the spa only. "contentUrl": "https://x1.adis.ws/v1/media/graphics/i/lesl/its-logo-wide",
Zeolite Market Share In 2022 | Top Players [ Shanghai Hengye, Zeotech Corp, Blue Pacific Minerals (BPM), UOP (Honeywell) ] In-Depth Analysis, Forecast to 2027 with Top Countries Data | The Twelfth Edition of Business Research Methods reflects a thoughtful revision of a market standard. I have water coming out the side of the sand filter where u would back wash? We recently had a makeover of our backyard where we replaced the concrete with pavers and it could very well be the sands and dust (yes, I had to vacuum the pool a couple times to get it clean) that got into the parts that helped speed up the demise of the pump. I have a 2 speed motor and the high will not start at start up. When tablets are used in the skimmers, Flex pipe beneath the skimmer can swell inside and begin to crimp and close (over many years time), so that a small amount of debris can clog the line. any ideas? Should be under warranty I would call the PB back out to troubleshoot it, or if not possible, contact the manufacturer of the control system. Hi Ann, in such cases, I would probably use a plumbers Pipe Wrench or very large Channel Pliers may work, or I have seen custom tools home-made from 24 wood, that fit over the ridge on the lid, with a few inches on either side to push on, or tap with a hammer. the tubes are sealed at the end by the two seal plates. Home / Pool Equipment / Pool Pumps / Hayward Pool Pump Troubleshooting. Please note: The majority of our literature and brochures are in English only. Troubleshooting pool heaters is a methodical process, or a process of elimination. This worked well until about 4 years ago, when I replaced it with a similar pump, a Hayward sp2607x10. Its just a trickle (as opposed to a spray)at this time. Impeller replacement is only ever really needed for breakage or other severe damage, so if it aint broke. I opened the back cover and made sure the shaft is rotating and also made sure the electric connections are good. just replaced t15 on a rev 1.45 aqua rite and the default salt reading now is 4. Is the wire size correct? Or buy a new motor. Hi Julie, is the FLO error code on the heater? Lets see what we can do I am a new pool owner and first Hayward pump. We have all these parts here: https://www.intheswim.com/c/valve-parts, I Installed a new Hayward VCSB216V solar pump. I checked the 20A fuse and it is good. I assume assy A motor is just bad. Hi Jack, according to the manual, the Drive Error Pump is Stalled error usually refers to water or moisture on the circuit board, under the display panel. I have mud in my filter so I guess I have a underground broken pipe. Went out today to find the lower plastic shroud melting again? Thanks! Thanks! The latest Lifestyle | Daily Life news, tips, opinion and advice from The Sydney Morning Herald covering life and relationships, beauty, fashion, health & wellbeing Following this procedure will identify News Reporter Reveals On Live TV That Shes Been Secretly Recording We would like to show you a description here but the site wont allow us. }
. Do you know what would cause this? Then back to no pressure. Any part # you can recommend ? I have been getting GFI breaker trips intermittently. In cases such as this, it is often wise to get things going sooner, and replace the pump (or motor) now, and sort out the money later unless you are able to cover the pool with a winter cover, to block the sun, or load up the pool with lots and lots of chlorine and daily brushing/skimming both of which could sustain the water for up to 2 weeks, in most cases. The idea is to cut the pipe above the pump, and crank the fitting 1/2 turn tighter, to open the crack, pump it full of superglue and then quickly unthread the pipe out of the pump, at which point the crack will close up, and hopefully seal up. Zeolite Market Share In 2022 | Top Players [ Shanghai Hengye, Zeotech Corp, Blue Pacific Minerals (BPM), UOP (Honeywell) ] In-Depth Analysis, Forecast to 2027 with Top Countries Data | A Answered on 5/26/2022 by InyoPools Product Specialist Craig C.. Hello J. Camfrog Pro Extreme Atau Gold - Camfrog Indonesia. If you see no gears moving, the timer motor may be dead. Replace with exact duplicated MFD numbers. If your hose has union connections that are tightened to connect to the filter, you may try some Teflon tape on the valve threads, or may need a new hose assembly, if the union threads are damaged. If from the top, try tightening the lid with a #3 Philips, or replace the lid o-ring. Yes, you can briefly test motors, for a few seconds without water, no problem. Also check that the ground wire is firmly attached at both ends, on the motor and the plug. Normally they last longer. If flushing and draining does not help, it is time to open up the filter tank, remove the grid assy (or flex tube nest), and after cleaning very well with a hose, soak it in a DE filter cleaner solution (5-gal bucket works well for Perflex). Similar pumps, with the same flow rate characteristics, are not less expensive. I do not see any water leaks around the pump or the filter other than a few drops under the chlorinator. My pump seems to trip the GFCI breaker each time it is plugged in. We have a Hayward 1.5 hp Superpump. Does the panel just need to dry or did I cause possible damage? registration, authorized "image": {
Hi Tim, If Assy A has a bad motor (test it? Motor wiring is pretty simple, green to ground and the other two wires, doesnt matter which one, go to terminals L1 and L2. Excuse my ignorance, but what could be the problem? I have tried a segmented hose and a one piece hose and when it starts to clean, it will clean for about 30 seconds and then there seems to be no water flowing into the pump. When you start the pump on low, on the panel it does say load 2 and load 3, "on". If they are within range, replace drive. Dec 14, 2021. ), is power, verify that power is leaving the timer and arriving at the motor. The switch or voltage selector, I believe it should be only over one tab, but check the owners manual, or the wiring diagram on the motor. Motors have a thermal overload switch to shut off the motor when it gets too hot. You have both filter pump and polaris pump on one timer? Or it could be an obstruction in the impeller, or anywhere before the impeller (clogged pipe, small pipe, partially closed suction valves, air leak) all of which will produce lower than normal filter pressure. Hope thats not the case. I set up to measure motor current, using 100amp, 100mv shunt, the current draw is 6.5 amps @241V (Pump pressure about 17-18 psi) Before purchasing the new pump, I replaced the breaker just to be safe, but it is still throwing the new one. But you could look further at the wires on the back of the terminal board, following them to the capacitor and switches problem lies where the power dies!